9761

Lower Ku-band up-converter 12.75-13.25 GHz

Short description

Lower Ku-band upconverter for the 12.75-13.25 GHz planned FSS band: converts 950-1450 MHz IF using an 11.8 GHz LO locked to an external 10 MHz reference, with 10 dBm P1dB, 5-30 dB gain, IP54 indoor housing and N-type connectors.

- +
  • Description
  • Downloads

The Lower Ku-band Upconverter 12.75-13.25 GHz addresses the 12.75-13.25 GHz uplink band allotted to the fixed-satellite service under the Appendix 30B plan of the ITU Radio Regulations. It converts 950-1450 MHz IF signals using an 11.8 GHz local oscillator locked to an external 10 MHz reference.

This planned band is used by regional and national satellite systems operating outside the conventional 14.0-14.5 GHz Ku-band uplink. The converter offers a minimum P1dB of 10 dBm and 5-30 dB gain in a 115x120x38 mm IP54 indoor enclosure (max 0.95 kg) powered from 10-24 VDC at under 9 W.

Input parameters
Input frequency range 950-1450 MHz
Input impedance 50 Ohm
Input/Output VSWR, max 1.5
Input interface N-type
Local Oscillator
LO frequency 11800 MHz
LO phase noise @10 Hz -35 dBc/Hz
LO phase noise @100 Hz -67 dBc/Hz
LO phase noise @1 kHz -77 dBc/Hz
LO phase noise @10 kHz -85 dBc/Hz
LO phase noise @100 kHz -97 dBc/Hz
LO phase noise @1 MHz -105 dBc/Hz
LO instability By external reference
Output parameters
Output frequency range 12.75-13.25 GHz
P1dB, min 10 dBm
Gain (fixed or adjustable) 5-30 dB
Gain adjustment (option) 5-30 dB
IMD3 (two tones) -30 dBc max, 2 signals 5 MHz apart @ 6 dB back-off from P1dB
Output interface N-type female
Output VSWR, max 1.5:1
RF isolation at ALARM, min -80 dB
Frequency Response
Flatness @ Full Band ±1 dB
Flatness @ 40 MHz ±0.4 dB
External reference 10 MHz
Spurious
Spurious @P1dB, max -60 dBc
LO leakage, without signal -75 dBm
Power Supply
Input voltage 10-24 VDC
Power consumption, max < 9 W
Environmental
Operating temperature -40°C to +60°C
Storage temperature -40°C to +95°C
Operating humidity Up to 60%, non-condensing (IP54)
Interfaces
LED monitoring 10 MHz locked status, Alarm
Mechanical
Dimensions 115x120x38 mm
Weight, max 0.95 kg

The Lower Ku-band Upconverter 12.75-13.25 GHz is a compact upconverter/BUC for the planned Ku-band FSS uplink. It translates 950-1450 MHz IF signals to 12.75-13.25 GHz with an 11.8 GHz local oscillator locked to an external 10 MHz reference.

The 12.75-13.25 GHz band belongs to the ITU Appendix 30B planned FSS allotments, which give countries guaranteed access to orbit and spectrum resources. Earth stations working with these national and regional systems need a converter dedicated to this segment rather than to the standard Ku-band uplink.

The unit delivers a minimum P1dB of 10 dBm, 5-30 dB gain, ±1 dB full-band flatness and ±0.4 dB over 40 MHz, with IMD3 -30 dBc max, spurious -60 dBc max @P1dB and LO leakage -75 dBm. N-type input and N-type female output simplify connection to modems and power amplifiers.

✅ Dedicated to the 12.75-13.25 GHz planned band

The converter is tailored to the lower Ku-band FSS uplink defined in the ITU Appendix 30B plan.

✅ Single 11.8 GHz LO

A single 11800 MHz local oscillator maps the 950-1450 MHz IF directly onto 12.75-13.25 GHz, locked to the external 10 MHz reference.

✅ Compact and energy-efficient

115x120x38 mm, max 0.95 kg, 10-24 VDC supply and power consumption below 9 W make the IP54 indoor unit easy to fit into existing racks.
🛠️ For national satellite systems, regional teleports or VSAT networks using the planned Ku-band, the Lower Ku-band Upconverter 12.75-13.25 GHz provides a ready-to-integrate uplink conversion stage.

🛒 Request pricing or configuration details for the Lower Ku-band Upconverter 12.75-13.25 GHz from our sales engineers.

📌 Key features

  • 12.75-13.25 GHz planned-band output

Output range matched to the Appendix 30B lower Ku-band FSS uplink.

  • 950-1450 MHz IF input

Standard L-band IF interface for satellite modulators.

  • 11.8 GHz LO with external reference

11800 MHz LO synchronized to an external 10 MHz reference; LO phase noise down to -105 dBc/Hz @1 MHz.

  • 10 dBm P1dB, 5-30 dB gain

Minimum P1dB of 10 dBm with gain fixed or adjustable within 5-30 dB (adjustment as an option).

  • Specified linearity

IMD3 of -30 dBc max for two signals 5 MHz apart at 6 dB back-off from P1dB.

  • LED monitoring

LED indication of 10 MHz lock and alarm status.

⚙️ Main functions

  • Planned-band upconversion

Converts 950-1450 MHz IF carriers into the 12.75-13.25 GHz uplink.

  • Frequency synchronization

Locks the 11.8 GHz LO to the station 10 MHz reference.

  • Output level control

5-30 dB gain sets the drive level for the uplink power amplifier.

  • Fault indication

LED alarm indication; RF isolation at ALARM specified at -80 dB min.

🧩 Applications

  • National satellite systems

Earth stations of national systems using Appendix 30B allotments.

  • Regional teleports

Teleports serving regional satellites in the lower Ku-band.

  • VSAT networks

VSAT hub uplinks operating in 12.75-13.25 GHz.

  • Government communications

Government satellite links in the planned Ku-band.

  • Satellite operator tracking

Satellite operator tracking applications that require stable IF-to-Ku-band conversion.

💡 Why you should buy from us❓

  • 1.5 years warranty
  • 7 years after-sales support
  • Remote support team of engineers
  • Discount program for regular customers 🎁

💬 Contact Us

For additional details or assistance regarding the Lower Ku-band Upconverter 12.75-13.25 GHz, feel free to contact our team. We provide professional consultation and aftersales support to help with integration, installation and setup of the upconverter within your satellite communication system.

Taking into consideration that we (UMT LLC) are developer and system integrator, also do not stop on our technical growth and improvement, know that view of all our devices and equipment including their technical parameters may be different from pictures presented on website and parameters listed on each device webpage.
Note! All details customer has to confirm in advance during ordering and before payment. Those parameters that were not specified and / or were not agreed while ordering will be implemented as basic at the discretion of the manufacturer. Each our customer has 1.5 year warranty and 7 year aftersales support for whole range of our products.